• ECO Steel Shutters
  • Insulated Shutters
  • Fire Shutters
  • Secure Shutters
  • Commercial Shutters
  • High Speed Shutters
  • Car Park Shutters
  • Sectional Doors
  • Folding Doors
  • Retail Grilles
  • Garage Doors
Emergency Repairs

Emergency
Repairs

Our 24 hour 365 day emergency repair service for all types of doors and roller shutters.

More Info
Emergency Repairs

Maintenance
Packages

Find out about Guardian Planned Preventative Maintenance and other tailored service agreements.

More Info
Architecture

Our
Products

View our comprehensive range of roller shutters and doors for all of your requirements.

More Info

Recent Projects

  • Bam Neasden

    Bam Neasden

  • BMW

    BMW

  • Essex Boatyard

    Essex Boatyard

  • Leigh Fire Station

    Leigh Fire Station

  • Orsett Fire Station

    Orsett Fire Station

  • Safestore

    Safestore

  • Seatrax

    Seatrax

  • Olympic Park

    Olympic Park

DIONYSUS WOODEN SHUTTERS

Beautiful materials for a superior finish

Timber shutter range - Our range of beautifully crafted timber roller shutters are suitable for a variety of applications.

T244 uses a timber lath in white oak, red oak, utile (mahogany), white ash, maple, red cherry and Colombian pine with an insert of either grey, black or blue plastic, stainless steel or aluminium. (Other insert options may be possible – please consult our sales department).

Due to the nature of this combination lath, this shutter will always be supplied with a factory finish to suit your own requirement.

Our T134 rolling grille, manufactured using our T134 (25mm) moulding where each alternate lath is omitted for a space of 229mm x 25mm to form an attractive single spaced grille effect, or with two laths removed for double spacing of 229mm X 50mm.

Guides are supplied in matching timber although they can be supplied in aluminium if desired.

We will always attempt to source other timbers as required. Laths are connected by steel aircraft cables concealed within the laths or by continuous zinc plated chain hinge on our T234 lath when over 2000mm clear high.


Tech Info

  • Max size: 2m x 2m
  • Weight: 12kg/m2

Roller Head Plate Sizes

  • Roller head plate size Height 1000mm > 1500mm -> 200 sq
  • Roller head plate size Height 1500mm > 2000mm -> 300 sq

Standard Specification

  • Guides 47mm x 47mm (revel fit) or 72mm x 47mm (face fit)

Colour Finish

  • "Renokil" Albi-Max Class 1 or 0 intumescent flame retardent coating
  • Stained clear
  • Natural untreated

General Options

Protective Bollards

We offer a range of protective bollards to prevent collision damage to your door set. Information on request.
  • Protective Bollards

    We offer a range of protective bollards to prevent collision damage to your door set. Information on request.

    Protective Bollards

    Angle Protection

    Floor fixed heavy duty angle protection.
    • Angle Protection

      Floor fixed heavy duty angle protection.

      Angle Protection

      Coil Casing

      Casing to cover the rear of the coil and motor.
      • Coil Casing

        Casing to cover the rear of the coil and motor.

        Coil Casing

        Fitting Configurations

        • Face fit
        • Reveal fit

        Security

        Keyswitch Lockbox

        Security box to protect externally mounted keyswitches.
        • Keyswitch Lockbox

          Security box to protect externally mounted keyswitches.

          Keyswitch Lockbox

          Anti-Tamper Controller

          Interfaces directly with a key switch, the shutter is made inoperable if the key switch is attacked by vandals or thieves. The system can also be linked to a burglar alarm further increasing security measures. Has a low voltage control circuit removing the risk of electric shocks, making the product ideal for use in public areas.
          • Anti-Tamper Controller

            Interfaces directly with a key switch, the shutter is made inoperable if the key switch is attacked by vandals or thieves. The system can also be linked to a burglar alarm further increasing security measures. Has a low voltage control circuit removing the risk of electric shocks, making the product ideal for use in public areas.

            Anti-Tamper Controller

            Pinlocks

            For additional security, pin locks can be added to a range of shutters. The lock fits into a casting on the roller shutters guide section. The pin fits through this casting and the roller shutter curtain to stop the curtain from attempts at lifting it. For electric doors a safety interlock is recommended to avoid accidentally attempting to open the shutter when locked.
            • Pinlocks

              For additional security, pin locks can be added to a range of shutters. The lock fits into a casting on the roller shutters guide section. The pin fits through this casting and the roller shutter curtain to stop the curtain from attempts at lifting it. For electric doors a safety interlock is recommended to avoid accidentally attempting to open the shutter when locked.

              Pinlocks

              Bottom Rail Lock

              ILS lock that connects to bottom bar and extends into guides for extra security.
              • Bottom Rail Lock

                ILS lock that connects to bottom bar and extends into guides for extra security.

                Bottom Rail Lock

                Safety

                Warning Lights

                Warning lights to alert users when doors are in operation.
                • Warning Lights

                  Warning lights to alert users when doors are in operation.

                  Warning Lights

                  Battery Backup

                  We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).
                  • Battery Backup

                    We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).

                    Battery Backup

                    Reflected Photoelectric Cell

                    This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.
                    • Reflected Photoelectric Cell

                      This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.

                      Reflected Photoelectric Cell

                      S/R Photoelectric Cell

                      This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.
                      • S/R Photoelectric Cell

                        This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.

                        S/R Photoelectric Cell

                        Safety Pressure Edge Wired

                        Installed on the door's bottom edge, the sensor when activated will return the door to the open position.
                        • Safety Pressure Edge Wired

                          Installed on the door's bottom edge, the sensor when activated will return the door to the open position.

                          Safety Pressure Edge Wired

                          Operation & Controls

                          Keypads

                          A range of keypads for PIN entry.
                          • Keypads

                            A range of keypads for PIN entry.

                            Keypads

                            Group Control

                            Allows multiple doors to be controlled with a single controller.
                            • Group Control

                              Allows multiple doors to be controlled with a single controller.

                              Group Control

                              Fire Brigade Switch

                              This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.
                              • Fire Brigade Switch

                                This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.

                                Fire Brigade Switch

                                Push Buttons

                                We offer a range of push button controls.
                                • Push Buttons

                                  We offer a range of push button controls.

                                  Push Buttons

                                  Biometric Controls

                                  Fingerprint reader control unit for extra security.
                                  • Biometric Controls

                                    Fingerprint reader control unit for extra security.

                                    Biometric Controls

                                    Standard Fire Door Interface Panel

                                    Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                                    • Amber when mains power is detected
                                    • Green when opening the shutter
                                    • Red when the shutter is closing
                                    The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated
                                    • Standard Fire Door Interface Panel

                                      Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                                      • Amber when mains power is detected
                                      • Green when opening the shutter
                                      • Red when the shutter is closing
                                      The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated

                                      Standard Fire Door Interface Panel

                                      Smoke & Heat Detector

                                      Will send a signal to close upon detecting smoke or excessive heat.
                                      • Smoke & Heat Detector

                                        Will send a signal to close upon detecting smoke or excessive heat.

                                        Smoke & Heat Detector

                                        Access Control Relay

                                        Card reader access control.
                                        • Access Control Relay

                                          Card reader access control.

                                          Access Control Relay

                                          RFID Radio Controls

                                          We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.
                                          • RFID Radio Controls

                                            We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.

                                            RFID Radio Controls

                                            • Remote Control - One touch operation
                                            • GSM Access
                                            • Software/network connection
                                            • Wind sensor
                                            • Sun sensor
                                            • Fire alarm activation

                                            Business Hours

                                            Monday - Friday
                                            8:00 to 17:00
                                            Saturday - Sunday
                                            Closed

                                            Our 24 hour emergency repair service is available every day - call 0800 7836602

                                            Privacy Policy & Cookies

                                            This website uses cookies that are necessary to its functioning and required to achieve the purposes illustrated in the privacy policy. By accepting this OR continuing to browse, you agree to our privacy policy.