Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks

GRILLE

grille1.jpg

grille.jpg

CP Model Overview

GUARDIAN CARPARK MODEL

DESIGNED FOR INTENSIVE USAGE

Designed for carpark applications this model is a 3 Phase electrically operated heavy duty rolling grille. The roller curtain is constructed from galvanised steel tubes and link sections 120 mm x 70 mm, held togther by galvanised steel rods.

Designed for excess of 200,000 run cycles and backed up by our warranty with maintenance packages the CARPARK-DD model provides a long term roller shutter grille solution.

FEATURES

  • Galvanised steel, tube and link roller curtain, Brickbond pattern as standard, inline pattern available
  • Opto Safety Edge
  • Reflective Photocell Safety
  • Fire Alarm connection*
  • Anti fall safety device
  • Door operation counter
  • Programmable timed closing
  • Maintenance alert display

 

pdficon.png

 

Download brochure and drawings - Here

  

txt-icon.pngDownload spec - Here

 

Recent Projects

Read about recent projects using this system - soon

 

 

Technical Information

Max Size 60 m2 approx

Larger sizes available

 

Fitting Configurations

  • Face Fix CP-DD
  • Revel Fix CP-FM

 

Roller Head Plate Sizes

  • Height 2000mm -> 4000mm = 350mm
  • Height 4000mm -> 5000mm = 400mm
  • Height 5000mm -> 6000mm = 450mm

 

Optional Upgrades

  • Coil Casing
  • Motor Casing
  • Intergration with access control systems
  • Different roller curtain options, including solid, perfoirated, cut resistant etc
  • Range of pedestrian access options
  • Anti vibration matting

 

Operation & Controls

  • Remote location
  • Remote control
  • Induction loops
  • Proximity Sensors
  • Radar detectors
  • Swipe Card
  • Digital Keypads

 

Safety

  • Operation warning light
  • Audio operation warning
  • Traffic lights
  • Protective bollards

 

Finish

  • Stainless Steel Construction
  • Polyester powder coat finish
  • Range of branding packages

 

Digital Control Systems for Industrial Doors

control_system_front

  • 1 touch open and close*
  • Digital door status display
  • Limit switch setting from ground level
  • Programmable door maintenance indicator
  • Plug connections between control panel and drive unti
  • Operations cycle counter (non-resettable)
  • Certified to BS EN 12453
  • Fault memorisation
  • Connection to BMS system via RJ45 connection
  • Connection for a variety of controls
  • Auto closing 1-240 seconds**

The Level 1, 2 and 3 control systems meet the requirements of BS EN 12453 and the introduction of a programmable maintenance indicator only further enhances the safety regime for the user and enables maintenance scheduling to be done on an operational basis.  * Level 2 model and above.  ** Requires optical safety edge system.

Click here for Level 1 Control System details

Click here for Level 2 Control System details

 

Maintenance Packages

Planned preventative maintenance

See our maintenance section or contact us for more information.

Guardians repair and maintenance services and engineers are accredited to the DHF's TS004 Repairs and maintenance standardand

Click here for more information.

Why have your door and shutter systems maintained?

  • It is a legal requirement - as failure to show evidence of maintenance could mean prohibition & enforcement notices being served and fines up to £5000 and imprisonment for 2 years. 'Safety In Use', the New European CEN Standards legislation - States that all types of door should be maintained in an efficient state, in efficient working order and in good repair. For further clarification visit www.dhfonline.org.uk.
  • Routine maintenance prolongs the operational life of the installation and ensures that the installation is kept in good working order.
  • It ensures that the door is working in a safe and efficient condition - helping to prevent accidents and damage which in turn results in down time, effecting work flow, productivity and resulting in loss of revenue.
  • It assists in identifying potential problems which can easily be rectified.

 

L20 DOORS / SHUTTERS / HATCHES

610 ROLLER SHUTTER

Save Specification

Product reference: GUARDIAN CAR PARK RANGE – CP

Performance: Not applicable

Arrangement: Vertical roller shutter

Accreditation: BS EN 1324

Online Informationhttp://www.guardiandoors.net/products/roller-shutters/car-park-range-apollo/cp-model/cp-model-overview

Designed for Carparks and high intensity usage, steel constriction, range of curtain options for air flow.

Dimensions

Opening height up to 4000mm, opening width up to 4000mm. Shutter weight: 35 kg/m² of door opening.

Curtain

As standard constructed from 75mm galvanized cold rolled scroll sections of suitable gauge, each alternate lath is fitted with a steel or nylon end lock to prevent lateral movement wind anchor locks on larger doors. The curtain can be modified in whole or part with the below options in red.

Curtain Modification

Perforations 2 mm O/D

Punchings 119mm w x 19 mm h Brick bond - Inline

Punchings 152mm w x 25 mm h Brick bond - Inline

Punchings 150mm w x 38 mm h Brick bond - Inline

Tube and link grille module 127mm w x 90 mm h Brick bond - Inline

Bottom Rail

The base of the curtain is fitted with a steel angle reinforcing rail of adequate size forming an inverted ‘T’.

Side Guides

Formed from cold rolled mild steel channel sections secured to the opening structure by full height mild steel fixing angles.

Roller Assembly

Constructed from steel tube, mounted on bright steel shafts running in ball races,

Endplates

The roller assembly is supported by steel endplates with mounting angles for fixing to the support structure.

Roller Enclosure (optional extra)

Formed from galvanised pressed sheet metal to enclose the rear of the shutter barrel and curtain assembly.

Operation

415v 50Hz 3 phase SafeDrive motor with emergency hand chain override

240v 50Hz 1 phase SafeDrive motor with emergency hand chain override (only used when necessary due to site power restrictions, the duty cycle of is reduced by 40%)

Control panel

With lcd status display, one touch impulse opening, hold to close. Also features maintenance alert system, fault recording, operation counter

Finish

Galvanised and primed ready to paint, Or powder coated to any standard BS or Ral number

Consult with Guardian Industrial Doors Ltd technical literature for details. Guardian Doors can also provide a design and specification advisory service and it is recommended that they are consulted early in the design process.

ManufacturerGUARDIAN INDUSTRIAL DOORS 45 Progress Road Leigh On Sea Essex, SS9 5PR Tel: 01702 512424. Fax: 01702 510015.

Email: mail@guardiandoors.com Web: www.guardiandoors.com

OPTIONS

Controls and operation

Key switch control unit – flush mounted

Key switch control unit – surface mounted

External weatherproof push button

Key lockable push button control

Group control unit for up to 6 shutters simultaneously (will require additional safety pressure edge.)

Radio controlled (will require additional safety pressure edge.)

Induction loop control

Radar detectors

Mobile phone operation module

Safety Systems

Safety bottom edge

Safety photo cell beam

Seals

Guide rail brush strip

Rubber bottom seal

Soffit brush strip

Finish

Powder coated to any standard BS or Ral number

Save Specification

level1_control_system

The Level 2 control system incorporates all Level 1 control features, plus:

level2_control_system