Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks

75.jpg

eco_dd5.jpg

eco-dd_ov1.jpg

eco_dd3.jpg

eco_dd4.jpg

Model Overview

ECONOMY RANGE ECO-ELECTRIC INDUSTRIAL

General Purpose Steel Electric Roller Shutter Models

 

The ECO-ELECTRIC 3 is the heavy duty model from the Economy range it is a 3 phase ( as standard ) electrically operated roller shutter door with a Flange Mounted or shaft mounted motor assembly.

ECO-DD - Shaft mounted motor configuration suitable for face fixinng

ECO-FM - Flange mounted motor configuration suitable for revel fixing

A low maintenance, economical. safe and secure shutter door suitable for frequent operation in industrial, commercial and agricultural environments where insulation is not a requirement.

Designed and tested for excess of 250,000 run cycles and backed up by our warranty and service packages.

 

PRODUCT ACCREDITATIONS

The ECO-DD and ECO-FM has been accredited to

BS EN 13241-1:2003

Industrial, commercial and garage doors and gates Product standard - Products w/out fire/smoke resistance

BS EN 12424:2000

Industrial, commercial and garage doors and gates. Resistance to wind load. Classification 3

BS EN 12453:2001

Industrial, commercial and garage doors and gates. Safety in use of power operated doors. 

 

pdficon.png

 

Download brochure and drawings - Here

 

  txt-icon.pngDownload spec - Here

 

Tech Info

Max Size 60 m2 approx

Larger shutters available speak to our technical department for more information.

 

Fitting Configurations

  • Face Fix   ECO - DD
  • Revel Fix   ECO - FM

     

Roller Head Plate Sizes

  • Height 2000mm -> 4000mm = 350mm
  • Height 4000mm -> 5000mm = 450mm
  • Height 5000mm -> 6000mm = 450mm

 

Standard Specifications

  • Galvanised steel construction
  • 3 Phase motor
  • Anti fall device
  • Hold to run operation
  • Plug in operation

 

Optional Upgrades

Security

  • AUTO BOLT - Heavy Duty Locking System
  • SENTINAL - Heavy Duty Security Barrier
  • ARES - Anti Cut Upgrade
  • Ground padlocks and or bullet locks with interlock safety
  • Anti Ram bollards
  • LPS 1175 Level 1, 2 , 3 and 4 Insurance upgraded specification

 

Operation & Controls

  • Airlock/Interlocking
  • Automatic operation* requires safety pressure edge or infa red safety beams
  • Remote control
  • Proximity Sensors
  • Radar detectors
  • Swipe Card
  • Digital Keypads
  • Pull Cords
  • Door status monitoring of modules at remote locations

 

Safety

  • Operation warning light
  • Audio operation warning
  • Traffic lights
  • Protective bollards
  • Guardian Clear view window module

 

Finish

  • HPS 200 Plastisol colour finish
  • Polyester powder coat finish to BS or RAL number
  • Range of corporate branding packages including full colour graphics

 

Digital Control Systems for Industrial Doors

control_system_front

  • 1 touch open and close*
  • Digital door status display
  • Limit switch setting from ground level
  • Programmable door maintenance indicator
  • Plug connections between control panel and drive unti
  • Operations cycle counter (non-resettable)
  • Certified to BS EN 12453
  • Fault memorisation
  • Connection to BMS system via RJ45 connection
  • Connection for a variety of controls
  • Auto closing 1-240 seconds**

The Level 1, 2 and 3 control systems meet the requirements of BS EN 12453 and the introduction of a programmable maintenance indicator only further enhances the safety regime for the user and enables maintenance scheduling to be done on an operational basis.  * Level 2 model and above.  ** Requires optical safety edge system.

Click here for Level 1 Control System details

Click here for Level 2 Control System details

 

Maintenance Packages

Planned preventative maintenance

See our maintenance section or contact us for more information.

Guardians repair and maintenance services and engineers are accredited to the DHF's TS004 Repairs and maintenance standardand

Click here for more information.

Why have your door and shutter systems maintained?

  • It is a legal requirement - as failure to show evidence of maintenance could mean prohibition & enforcement notices being served and fines up to £5000 and imprisonment for 2 years. 'Safety In Use', the New European CEN Standards legislation - States that all types of door should be maintained in an efficient state, in efficient working order and in good repair. For further clarification visit www.dhfonline.org.uk.
  • Routine maintenance prolongs the operational life of the installation and ensures that the installation is kept in good working order.
  • It ensures that the door is working in a safe and efficient condition - helping to prevent accidents and damage which in turn results in down time, effecting work flow, productivity and resulting in loss of revenue.
  • It assists in identifying potential problems which can easily be rectified.

 

L20 DOORS / SHUTTERS / HATCHES

610 ROLLER SHUTTER

Save Specification

Product reference: GUARDIAN ECO RANGE – ECO-DD MODEL

Performance: Not applicable

Arrangement: Vertical roller shutter

Accreditation: BS EN 1324

Online Information http://www.guardiandoors.net/products/roller-shutters/economy-range-zeus/eco-electric-3-phase/model-overview

A multipurpose steel vertically operated roller shutter available with either solid punched or perforated curtain. See our PDF Curtain modifications, or ask for cosmetic options.

Dimensions

Opening height up to 8000mm, opening width up to 8000mm. Shutter weight: 35 kg/m² of door opening.

Curtain

Constructed from 75mm galvanized cold rolled scroll sections of suitable gauge, each alternate lath is fitted with a steel or nylon end lock to prevent lateral movement and wind anchor locks on larger doors.

Curtain Modification

Perforations 2 mm O/D

Punchings 119mm w x 19 mm h Brick bond - Inline

Punchings 152mm w x 25 mm h Brick bond - Inline

Punchings 150mm w x 38 mm h Brick bond - Inline

Bottom Rail

The base of the curtain is fitted with a steel angle reinforcing rail of adequate size forming an inverted ‘T’.

Side Guides

Formed from cold rolled mild steel channel sections secured to the opening structure by full height mild steel fixing angles.

Roller Assembly

Constructed from mild steel tube of sufficient gauge to prevent deflection, mounted on bright steel shafts running in ball races, reduction drive gearing where applicable is by machine cut steel gears or chain drive to suit the size of the opening.

Endplates

The roller assembly is supported by mild steel endplates with mounting angles for fixing to the support structure.

Roller Enclosure (optional extra)

Formed from galvanised pressed sheet metal to enclose the rear of the shutter barrel and curtain assembly.

Operation

DD MODEL 415v 50Hz 3 phase SafeDrive - motor with emergency hand chain override

Control panel

With lcd status display, one touch impulse opening, hold to close. Also features maintenance alert system, fault recording and operation counter.

Finish

Galvanised and primed ready to paint, Or powder coated to any standard BS or Ral number

 

Consult with Guardian Industrial Doors Ltd technical literature for details. Guardian Doors can also provide a design and specification advisory service and it is recommended that they are consulted early in the design process.

Manufacturer: GUARDIAN INDUSTRIAL DOORS 45 Progress Road Leigh On Sea Essex, SS9 5PR Tel: 01702 512424. Fax: 01702 510015.

 

OPTIONS

Controls and operation

Key switch control unit – flush mounted

Key switch control unit – surface mounted

External weatherproof push button

Key lockable push button control

Group control unit for up to 6 shutters simultaneously (will require additional safety pressure edge.)

Radio controlled (will require additional safety pressure edge.)

Safety Systems

Safety bottom edge

Safety photo cell beam

Security

Ground locks and interlock facility

Bullet lock interlock box

Save Specification

level1_control_system

The Level 2 control system incorporates all Level 1 control features, plus:

level2_control_system