Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks

Flex Edge

EROS SPEED RANGE - Flex Edge Model

Ultra Safe Soft Bottom Edge

The Guardian Speed Flex Edge is an electrically driven High Speed
door for use in industrial and utility buildings for interior
applications. It can be used for energy saving, draught exclusion,
climate control and the partitioning of rooms.
  

pdficon.png

 

Download brochure and drawings -Here

 

 

Components and construction

The Guardian Speed Flex Edge has a door leaf 1.2 mm thick made of a polyester-
reinforced PVC with a transparent vision section between
approx. 1200 and 1800 mm from the floor. The closing side of the
door curtain consists of a flexible soft bottom beam.

The extruded aluminium columns ensure the guidance of the door
leaf. These form one taut unit with the brackets for the fastening of
the roller and protective hood. From 12 m2 door balancing is applied
as standard.

Materials

The guides and the roller are aluminium. The protective hood is
PVC. All PVC parts used can be recycled.


 

Colours

The door curtain is available in the colours blue (standard), orange,
yellow, black, grey, red or white and is provided as standard with a
vision section.


 

Dimensions

• max. width (W) ...................................................................3500 mm
• max. height (H) ..................................................................5000 mm
• max. surface area (W x H)....................................................17.5 m2
• max. wind force ...............................................................5 Beaufort
• lateral space at the guides .................................................160 mm
• depth top hood ....................................................................420 mm
• required fitting depth for the top hood...............................650 mm
• required space above .........................................................600 mm.


 

Drive

The drive consists of an industrial tube motor assembled in the
roller. As a result the necessary lateral space is minimal. The drive
is on the right-hand side of the roller as standard


 

Control and operation

The control system regulates a multitude of functions such as:
• adjustable open time
• continuously variable speed regulation by frequency control for

opening and closing the door

• service and run mode
• 7-segment display for controlling the various functions
• choice of permanently open or permanently shut


Other forms of operation that can be connected to the

standard control box are:
• operation by pull switch, key-operated switch, push-button,
photocell, radar, induction loop detection or by radio control
with transmitter and receiver.


 

Performance

• opening speed ................................................................max. 2 m/s
• closing speed ..........................................................approx. 0.5 m/s


 

Protection

• safety photocell in the columns approx. 250 mm from the floor
for doors up to 12 m2

• doors from 12 m2 are provided with a safety light curtain (IP65
and to max. height of 2500 mm). If this curtain is interrupted by
an obstacle the door will automatically fully open until the
screen is freed again.


 

Structural provisions and connection

• in normal circumstances no special structural provisions are
required for the assembly and fitting of a Guardian Speed Flex Edge. The
self-supporting construction must only be fixed at the floor and
the roller

• there must be a wall socket within a radius of 500 mm of where
the control box will be positioned for the electrical connection
(CEE form blue, 1 x 230V fused, slow operation 16 A and fitted
with an circuit-breaker of at least 300 mA). As standard this is
fitted at a height of approx. 1500 mm from the floor on the drive
side.


 

Technical details electric motor

mains voltage..............................................LNPE~230V/50Hz/16AT
degree of protection ..................................................................IP55
consumed power .........................................................max. 2,2 kW.


 

UPGRADES

Control and operation

• operation by push-buttons, pull switches, photocell, radar,
induction loop or by radio control. Other forms of operation on
request

• ‘half height’ setting (for personnel access)
• door interlock control in combination with another door
• integrated and illuminated push-button set (open-stop-close) in
the guide column
• illuminated push-button set (open-stop-close) in surfacemounted
box.


 

Protection

• light screen to a max. height of 2500 mm for doors < 12 m2
instead of the safety photocell
• connection of traffic lights (red/green or red and green) or
orange flashing light
• extra safety photocell approx. 400 mm from the floor
• mechanical emergency unlocking (after unlocking the door opens).


 

Construction

• guide columns in customer-specified RAL colour (powder coating)
• PVC hood over the roller and drive
• full colour printing of the door panel (on request).


 

Maintenance Packages

Planned preventative maintenance

See our maintenance section or contact us for more information.

Guardians repair and maintenance services and engineers are accredited to the DHF's TS004 Repairs and maintenance standardand

Click here for more information.

 

Why have your door and shutter systems maintained?

  • It is a legal requirement - as failure to show evidence of maintenance could mean prohibition & enforcement notices being served and fines up to £5000 and imprisonment for 2 years. 'Safety In Use', the New European CEN Standards legislation - States that all types of door should be maintained in an efficient state, in efficient working order and in good repair. For further clarification visit www.dhfonline.org.uk.
  • Routine maintenance prolongs the operational life of the installation and ensures that the installation is kept in good working order.
  • It ensures that the door is working in a safe and efficient condition - helping to prevent accidents and damage which in turn results in down time, effecting work flow, productivity and resulting in loss of revenue.
  • It assists in identifying potential problems which can easily be rectified.