AdWords Click Fraud

SGS

Fire Resistant Sliding Door

The fire-resistant sliding door is an excellent solution for situations where high fire-resistant is required combined with specific end user design needs.

The maximum fire-resistant will depend on the size and model of the door, ranges up to 90 minutes (for the EI(1) requirement), based on two-sided testing in accordance with EN 1634-1, or 120 minutes (for the EI(2) and EW requirements).

The sliding door can optionally be manufactured as a double wing sliding door, with both wings sliding in the same direction or away from each other, or as a telescopic sliding door, with several wings sliding parallel with each other. A unique feature of this door is the option to integrate it with an emergency exit door, without a threshold, thereby allowing the fire-resistant sliding door to be incorporated into a building’s emergency escape route.

The fire-resistant sliding door comes standard as a manually operated door fitted with a speed controller and integrated magnetic door catch. However, the sliding door can optionally be fitted with an electric drive system. The sliding doors can also be fitted with a special drive and motion detectors to make the doors suitable for high frequency use.

The fire-resistant sliding door has successfully undergone two-sided smoke resistance testing at Efectis Nederland in accordance with EN 1634-3 at both Sa 20 (cold smoke at approx. 20 degrees Celsius) and Sm 200 (hot smoke at approx. 200 degrees Celsius).

Product Downloads
Product Certifications
Tech Info
Please see our brochure for full technical info.

Standard Specification
  • Steel tube frame bonded to the fire resistant plating
  • Horizontal sliding rail system
  • Activation via 24V fire alarm connection
Warranty

Peace of Mind Warranties

All our products are guaranteed against defect of material or workmanship by Guardian Doors, subject to correct, maintenance and operation, for a period of 12 months from the date of installation. We offer extended warranties for up to 5 years with an agreed maintenance contract. Contact us for more details.

FAQ

Coming soon...

Options

General Upgrades

Select an image for more information:

Protective Bollards

Protective
Bollards

Guardian Doors Floor Fixed Heavy Duty Angle Protection

Angle
Protection

 
Fitting Configurations
  • Face Fix
  • Revel Fix
Safety

Select an image for more information:

Guardian Doors Operational Warning Lights

Warning
Lights

Guardian Doors Battery Backup System

Battery
Backup

Guardian Doors Photoelectric Cell Reflected

Photoelectric
Cell Reflected

Guardian Doors Photoelectric Cell Send and Receive

Photoelectric
Cell S/R

Guardian Doors Safety Pressure Edge Wired

Safety Pressure
Edge Wired

 
  • Illuminated status indicators
Operation & Controls

Controls

Select an image for more information:

Mushroom Push Button

Mushroom
Push Button

Fire Brigade Switch

Fire Brigade Switch

Push Buttons

Push Buttons
 

Biometric Controls

Biometric
Controls

Guardian Doors Access Control Relay

Access Control
Relay

Guardian Doors Hands Free RFID Controls

RFID Radio
Controls

 
  • GSM Access
  • Software / Network connection
  • Wind Sensor
  • Sun sensor
  • Fire Alarm Activation
Activation Methods In A Fire

The primary activation method for fire shutters is via the main fire alarm system. The signal from the fire alarm is routed via one of the below control units, giving the shutter a command to close.

In situations where there is no main fire alarm panel we can provide a standalone system that activates the fire alarm via one of the methods below as indicated with a * (please note for a standalone system an Audio Visual FDI panel is required).

Standard Fire Door Interface Panel

Standard Fire Door
Interface Panel

Audio Visual FDI Panel – FCP03

FCP03 Audio
Visual Panel

Audio Visual FDI Panel – EMC3B

EMC3B Audio
Visual Panel

Guardian Doors Smoke and Heat Detector

Smoke & Heat
Detector*

Guardian Doors Fusible Link

Fusible
Link*

 
Finish
  • Polyester powder coat finish to BS colour or RAL number
  • Range of corporate branding packages including full colour graphics
  • Galvanised
Maintenance Packages

Planned preventative maintenance

See our maintenance section or contact us for more information. Guardian's repair and maintenance services and engineers are accredited to the DHF's TS004 Repairs and Maintenance standard.

It is a legal requirement - as failure to show evidence of maintenance could mean prohibition & enforcement notices being served and fines up to £5000 and imprisonment for 2 years. 'Safety In Use' - the New European CEN Standards legislation - states that all types of door should be maintained in an efficient state, in efficient working order and in good repair. For further clarification visit www.dhfonline.org.uk.

Routine maintenance prolongs the operational life of the installation and ensures that the installation is kept in good working order - helping to prevent accidents and damage which in turn results in down time, effecting work flow, productivity and resulting in loss of revenue. It assists in identifying potential problems which can easily be rectified.

Peace-of-Mind Warranties

All our products are guaranteed against defect of material or workmanship by Guardian Doors, subject to correct maintenance and operation, for a period of 12 months from the date of installation.

Registered Office

45 Progress Road
Leigh-on-Sea
Essex
SS9 5PR
0800 7836602
+44 (0)1702 260117
This email address is being protected from spambots. You need JavaScript enabled to view it.

Established in 1979, Guardian Industrial Doors design, manufacture, supply and maintain industrial and commercial roller shutters, doors and gates.

©2015 Guardian Doors