Insulated Sectional Door

iso4.jpg

iso8.jpg

iso1.jpg

vp6.jpg

vp4.jpg

vp3.jpg

vp1.jpg

vp2.jpg

alu4.jpg

alu5.jpg

Insulated ISO

Insulated - ISO Model

High Quality Modern Styling, Excellent Insulation

The Guardian ISO sectional door is made up of panels that combine excellent thermal insulation 1.8W/m2/K 4m x 4m installed door set ) and sound-deadening properties with modern panel styles. These qualities make the ISO sectional door hard to beat in terms of performance and appearance.

There is a wide choice of vision panels and windows, the RAL colour palette is very extensive and wicket doors can be incorporated in or placed next to the sectional door.

A high quality sectional door that blends in perfectly with modern styling trends in industrial and commercial architecture.

 

pdficon.png

 

 

Download brochure

 

Recent Projects

Rayleigh Fire Station - Click Here

 

Tech Info

  • Max Size 7m x 7m.
  • Weight - 15 kg pms.
  • U value 1.8W/m2/K 4 x 4 m installed door set.

 

Track Configurations

 

Low Headroom

T 240 track system - MAX DOOR SIZE 22m2

The T 240 system is normally used when a headroom of 240 mm is available above the clear opening. A rectangular tube profile is mounted at the rear of the horizontal tracks. The spring assembly is fastened to this tube. This system can also be used if the headroom above the clear opening is less than 240 mm. In such cases, the sectional door will remain visible in the clear opening when the door is fully open.

 

Track---340.jpg

T 340 track system - MAX DOOR SIZE 22m2

The T 340 system is suitable for standard situations. This system is used when a headroom of 340 mm is available above the clear opening. A rectangular tube profile is mounted at the rear of the horizontal tracks. The spring assembly is fastened to this tube.
This type of track system is an excellent solution in cases when the available headroom of 340 mm is not suitable for other track systems. For example, if a glazed element is located above the clear opening or the wall above the opening is constructed from cellular concrete. In the first instance, the spring assembly would be visible from the outside. In the second instance, the material above the opening is not robust enough to carry the weight of the spring assembly.

 

Track---430.jpg

T 450 track system - MAX DOOR SIZE 50m2

The T 450 system is used as standard when a headroom of 430 to 700 mm is available above the clear opening. The spring assembly is fixed to the building wall in this case

 

Track---400.jpg

T 400 track system - MAX DOOR SIZE 50m2

The T 400 system is used when a headroom of 700 to 3400 mm is available above the clear opening. The vertical tracks follow the wall line until the roof is reached and then curve through the appropriate angle to lie parallel to the roof. The spring assembly is mounted to the vertical wall just under the roof.

 

Track---Vertical-lift.jpg

T 500 track system - MAX DOOR SIZE 28m2

This track system is used when the available headroom is sufficient to allow the sectional door to open vertically. The spring assembly is fixed to the wall at the top of the tracks.

 

Track---Vertical-lift-hf.jpg

T 500 HF track system - MAX DOOR SIZE 16m2

This track system is used when the available headroom is sufficient to allow the sectional door to open vertically. The spring assembly is fixed to a mounting arrangement at approx 500 mm above the clear opening. The door width may not exceed 4000 mm when this system is used.The low-level spring assembly simplifes drive and spring arrangement maintenance and repairs.


Optional Upgrades

  • Variety of vision panels
  • Operation warning light
  • Audio operation warning
  • Traffic lights
  • Protective bollards

 

Security Upgrades

 

Operation & Control Options

  • Airlock / Interlocking
  • Automatic operation* requires safety pressure edge or infa red safety beams
  • Remote control / operation
  • Proximity Sensors
  • Radar detectors
  • Swipe Card
  • Digital Keypads

 

Finish Options

  • HPS 200 Plastisol colour finish
  • KINGSPAN XL 2000 finishes
  • Polyester powder coat finish to BS or RAL number
  • Range of corporate branding packages including full colour graphics

 

 

Digital Control Systems for Industrial Doors

control_system_front

  • 1 touch open and close*
  • Digital door status display
  • Limit switch setting from ground level
  • Programmable door maintenance indicator
  • Plug connections between control panel and drive unti
  • Operations cycle counter (non-resettable)
  • Certified to BS EN 12453
  • Fault memorisation
  • Connection to BMS system via RJ45 connection
  • Connection for a variety of controls
  • Auto closing 1-240 seconds**

The Level 1, 2 and 3 control systems meet the requirements of BS EN 12453 and the introduction of a programmable maintenance indicator only further enhances the safety regime for the user and enables maintenance scheduling to be done on an operational basis.  * Level 2 model and above.  ** Requires optical safety edge system.

Click here for Level 1 Control System details

Click here for Level 2 Control System details

 

Maintenance Packages

Planned preventative maintenance

See our maintenance section or contact us for more information.

Guardians repair and maintenance services and engineers are accredited to the DHF's TS004 Repairs and maintenance standardand

Click here for more information.

Why have your door and shutter systems maintained?

  • It is a legal requirement - as failure to show evidence of maintenance could mean prohibition & enforcement notices being served and fines up to £5000 and imprisonment for 2 years. 'Safety In Use', the New European CEN Standards legislation - States that all types of door should be maintained in an efficient state, in efficient working order and in good repair. For further clarification visit www.dhfonline.org.uk.
  • Routine maintenance prolongs the operational life of the installation and ensures that the installation is kept in good working order.
  • It ensures that the door is working in a safe and efficient condition - helping to prevent accidents and damage which in turn results in down time, effecting work flow, productivity and resulting in loss of revenue.
  • It assists in identifying potential problems which can easily be rectified.

 

level1_control_system

The Level 2 control system incorporates all Level 1 control features, plus:

level2_control_system